Winter Special Sale - Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 575363r9

Welcome To DumpsPedia

QSSA2018 Sample Questions Answers

Questions 4

A system administrator needs to grant an auto login access pass for directory (ABC) users.

Which configuration will meet this requirement?

A)

B)

C)

D)

Options:

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Buy Now
Questions 5

Poor performance has been reported in a Qlik Sense environment. End users are losing connectivity to the system. When end users are eventually able to log in after many attempts, navigation and app consumption is slow. Long response times each click are also reported.

A system administrator confirms the following:

* The network is stable and has good throughput

* The QliK Sense server is running virtual on dedicated resources with high-end CPUs

* The number of users in the system has NOT incrased

* The data model has NOT changed

* The number and size of apps have increased over time

Which combination of tools should be used to diagnose this issue?

Options:

A.

Governance Dashboard, ipconfiq. tracert. Wireshark, and the System Monitor app

B.

Process Explorer from Sysinternals. Windows Task Manager, Windows Event Viewer, and the Operations Monitor app

C.

Windows Task Manager. Windows Event Viewer. Windows Explorer, and Process Monitor from Sysmternals

D.

Wireshark, Disk Usage from Sysmternals, Windows Task Manager, and the Operations Monitor app

Buy Now
Questions 6

Refer to the exhibit.

Qlik Sense Enterprise is deployed in a multi-node environment. The environment is sequence into a central, a scheduler, and a consumer node. A system administrator routinely performs updates and available that the system accepts the updates correctly. The system administrator notices that reloads of the License Monitor Operations Monitor fail with this message.

What should the system administrator do to resolve this issue?

Options:

A.

1. Open the QMC and go to Data connections

2. Modify all qrs-data connections and change the security for DataConnection_* to Read access

3. Change the owner on all qrs-data connections from INTERNAL/sa_repository to the Qlik Sense service account Reboot the server

4. Open the QMC and reload the monitoring apps

5. Open the QMC and go to Data connection

B.

1. Open the QMC and got to Data connections

2. Delete the qrs-data connections

3. Perform a Qlik Sense Enterprise repair installation

4. Reboot the server

5. Open the QMC and reload the monitoring apps

C.

1. Open the QMC and go to Data connection

2. Delete the qr_data connections

3. Manually Import the latest License Monitor and Operations Monitor

4. Remove the old Lisense Monitor and Operations Monitor

5. Open the QMC and reload the new monitoring apps

D.

1. Open the QMC and go to Data connections

2. Delete the qrs-data connections, and recreate them manually

3. Manually import the latest License Monitor and Operator Monitor

4. Change the owner on all qrs-data connections from INTERNAL\sa repository to the Qlik Sense account

5. Open the QMC and reload the new monitoring apps

Buy Now
Questions 7

A system administrator has to set up three physical servers and one virtual server for a new Qlik Sense Enterprise environment. Four separate nodes are required.

The physical servers have 32 GB of RAM The virtual server haft S GB of RAM

Which node should be virtualized?

Options:

A.

Proxy

B.

Scheduler/Reload

C.

Central

D.

Engine

Buy Now
Questions 8

A system administrator must design a Qlik Sense server architecture that meets the following requirements

* Approximately 1000 users will be using apps

* Apps are reloaded outside of office hours

* The total size of data in all apps will be approximately 600 million rows

* Apps must be available 24/7

Which architecture meets these requirements in the most cost efficient way?

A)

B)

C)

D)

Options:

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Buy Now
Questions 9

Refer to the exhibit.

A contentAdmin user discover TASK_RELOAD_APP2 fails.The user double cliks the Failed task to open the Edit reload task screen. There are NO isse found in the Edit reload task screen. The user opens the Operations Monitor app, and the finds an error message in the Details sheet.

Message from reloadprovider: Reload Failed in Engine. Check Engine or script logs

The Engine log did NOT provide any reason for the failure?

Which is the most efficient methods to the cause of this issue?

Options:

A.

On the Failed task, click the information icon in te Status field, then click Download script log

B.

Navigate to C:\ ProgrameData|Sense\\Log, then open and review the most recent file

C.

Navigate to C:\Programe Files\Qlik\Sense\Logging, then open and review the most recent file

D.

In the QMC, select Audit, select Reload Tasks under Target resource, then click Audit and review

Buy Now
Questions 10

A business analyst creates and tests an app on Qlik Sense Desktop. The analyst sends the QVF file to a system administrator and requests the tile to be imported into Qlik Sense Enterprise.

The system administrator imports the file, but the data reload fails. The administrator imports and opens the app in the Qlik Sense Desktop, then realizes that Section Access has been implemented

What is causing this issue with the reload on the server?

Options:

A.

The system administrator did NOT import the data connection and apply Section Access

B.

The sa_scheduler entry is missing in the Section Access table

C.

The Qlik Sense service account is missing in the Section Access table

D.

The ContentAdmin role was NOT assigned to the business analyst

Buy Now
Questions 11

A system administrator must set up security that does NOT allow certain users to create objects in published apps. The users that should NOT be able to create objects are in an AD group called LimitedUsers.

Which security rule should the administrator use to meet this requirement?

Options:

A.

Resource filter App_*

Action Create

Rule Condition: (resource, objectType=charts’’ and user group=’’ LimitedUsers’’)

Context Both in hub and QMC

B.

Resource filter App_*

Action Create

Rule Condition: (resource, objectType=charts’’ and user group=’’ LimitedUsers’’)

Context: Only in hub

C.

Resource filter App_*

Action Create

Rule Condition: (resource, objectType=charts’’ and user group=’’ LimitedUsers’’)

Context: Both in hub and OMC

D.

Resource filter App_*

Action Create

Rule Condition: (resource, objectType=charts’’ and user group=’’ LimitedUsers’’)

Context: Only in hub

Buy Now
Questions 12

Which option should the system administrator recommend?

Options:

A.

Run Microsoft Windows Updates to prepare Windows Server 2008 R2 for the latest QliK Sense version

B.

Download the latest patch, Qlik_Sense_update exe, and install it using Windows compatibility mode

C.

Upgrade to Microsoft Windows Server 2012 or later

D.

Upgrade only up to the Qlik Sense February 2018 version

Buy Now
Questions 13

A system administrator is creating a user directory connector (UDC) for an Active Directory using SSL Which path should the administrator use to configure the UDC?

Options:

A.

tls //company domain com/ssI

B.

https //company domain, com

C.

ldaps://compatiy domain com

D.

Idap //company domain com/ssI

Buy Now
Questions 14

A system administrator has a Qlik Sense environment with a central node and a scheduler node. One of the apps loads data from text files which are located in the FinanceData folder on the D drive on the central node

The system administrator creates a folder data connection and sets Name = Finance Data and Path = D :\FinanceData

When the reload task runs for lint firs! lime, it tails

What is the cause of the error?

Options:

A.

The network share is NOT configured yet

B.

Resources are limited in the current scheduler node

C.

Port 4747 was NOT opened on the central node

D.

Access permissions to the FinanceData folder are No granted to users

Buy Now
Questions 15

A Qlik Sense environment has users from Active Directory A system administrator creates a task to synchronize the users from Active Direct with Qlik Sense.

The system administrator adds a new user to Active Directory, and manually executes the synchronization tasks in Qlik Sense. The administrator observes that the new user NOT added to the Qlik environment.

What should the system administrator do to ensure the new user is added?

Options:

A.

Look for an LDAP filter on the UDC for users from Active Directory

B.

Ensure he sycnhronization task has been sufficient

C.

Wait 10 minutes for the new user in Active Directory to become visible for QIik Sense

D.

In the UDC, check Sync user data for existing users and re-run the synchronization task

Buy Now
Exam Code: QSSA2018
Exam Name: Qlik Sense System Administrator Certification Exam - June 2018 Release
Last Update: Nov 21, 2024
Questions: 50
$64  $159.99
$48  $119.99
$40  $99.99
buy now QSSA2018