Winter Special Sale - Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 575363r9

Welcome To DumpsPedia

NS0-593 Sample Questions Answers

Questions 4

You have a customer complaining of long build times from their NetApp ONTAP-based datastores. They provided you packet traces from the controller and client. Analysis of these traces shows an average service response time of 1 ms. QoS output confirms the same. The client traces are reporting an average of 15 ms in the same time period.

In this situation, what would be your next step?

Options:

A.

The cluster is responding slowly and requires further investigation using performance archives.

B.

The client that reports high latency should be investigated.

C.

The cluster interconnects should be investigated.

D.

A sync core should be triggered.

Buy Now
Questions 5

When an administrator tries to create a share for an existing volume named voll, the process fails with an error.

Referring to the exhibit, what Is the reason for the error?

Options:

A.

The volume must have a type of DP.

B.

The volume has not been mounted.

C.

The CIFS service is not authenticating properly with the domain controller.

D.

The CIFS service is not in workgroup mode.

Buy Now
Questions 6

You have a NetApp ONTAP cluster consisting of four NetApp FAS8200 controllers with two NetApp CN1610 cluster switches running ONIAP 9.8 software. You are receiving several alert messages stating that the cluster network has degraded. After troubleshooting, you determine that the errors are being generated from Node 2, interface e0b.

In this scenario, what should you do first to solve this problem?

Options:

A.

Replace the Twinax cable between Node 2, Interface e0b. and the NetApp CN1610 switch.

B.

Replace the motherboard on Node 2.

C.

Replace both NetApp CN1610 switches.

D.

Replace the NetApp CN1610 switch that connects to Node 2, interface e0b.

Buy Now
Questions 7

You Just used the CLI to create a NetApp ONTAP FlexGroup Volume on a NetApp Cloud Volumes ONTAP instance. After creation, you notice odd behavior in NetApp Cloud Manager.

In this scenario, what Is the reason for this behavior?

Options:

A.

Cloud Volumes ONTAP does not support FlexGroup volumes.

B.

The Capacity Management Mode within Cloud Manager should be set to Manual.

C.

The Capacity Management Mode within Cloud Manager should be set to Automatic.

D.

Cloud Manager must be used to provision the FlexGroup volume.

Buy Now
Questions 8

You have connection Issues from a Linux host to an AFF A400 FC LUN. You are asked by support to run the NetApp sanlun command to provide troubleshooting information.

Which NetApp software package must be installed on the host?

Options:

A.

Virtual Storage Console

B.

Inventory Collect Tool

C.

Host Utilities package

D.

SnapDrive for UNIX

Buy Now
Questions 9

A customer reports that while Installing Windows updates on their external Vscan servers, clients could not access any files on their CIF-S SVM. The problem disappeared after the update process was completed. The customer wants to prevent this issue from happening during the next patch window.

In this scenario, what are two ways to accomplish this task? (Choose two.)

Options:

A.

Enable the -scan-mandatory flag in the Vscan policy.

B.

Update the Vscan servers one at a time.

C.

Modify the CIFS shares to be continuously available (CA) shares.

D.

Disable the -scan-mandatory flag in the Vscan policy.

Buy Now
Questions 10

The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02. Node-02 panics showing the string below.

PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess fnmbx_instanceWorker on release 9.5P8 (C)

What has happened in this situation?

Options:

A.

While in maintenance mode, the sldiag device show command was executed.

B.

While in maintenance mode, the fcadmin device_map command was executed.

C.

While in maintenance mode, the HA_config show command was executed.

D.

While in maintenance mode, the mailbox destroy local command was executed.

Buy Now
Questions 11

After a normal power down of both nodes for building maintenance, Node01 of a 2-node cluster cannot be powered back up; however, all disk shelves are powered.

Which action should be performed to bring the cluster online and allow Node02 to serve data?

Options:

A.

Recreate the cluster with the system configuration recovery cluster recreate -from node command.

B.

Reboot the node With the system node reboot -node Node02 -bypass-optimization true command.

C.

Perform a takeover with the storage failover takeover -ofnode Node01 -option force command.

D.

Reinitialize the cluster with option 4a from the boot menu.

Buy Now
Questions 12

A customer wants to connect a NetApp AFF A700 system to a 40GbE switch. The controllers have a 10/40G Ethernet card in slot 4 for this purpose. The link comes up fine on node 2, but it will not come up on node 1. You look at the AutoSupport data for the nodes in question and see the output shown in the exhibit.

What is the cause of the customer's problem?

Options:

A.

The cable is plugged in upside down.

B.

The incorrect cable is used.

C.

The ports are configured for 4x10Gbit instead of 40Gbit.

D.

The port has an incorrect SFP inserted.

Buy Now
Questions 13

After a motherboard replacement on a NetApp AFF A300 in a SAN environment, the customer states that ports 0e and 0f are unable to connect to the fabric. The ports report "offline".

What would you examine first to troubleshoot the issue?

Options:

A.

vserver fcp wwpn-alias show command output

B.

system node hardware unified-connect show command output

C.

storage port show command output

D.

vserver fcp interface show command output

Buy Now
Questions 14

You are optimizing your Cloud Volumes ONTAP. For interoperability and consolidation purposes, you need to know the storage limits.

In this scenario, which source should be reviewed?

Options:

A.

NetApp Cloud Volumes ONTAP Release Notes

B.

Hardware Universe

C.

Interoperability Matrix Tool (IMT)

D.

Cloud Central

Buy Now
Questions 15

An administrator receives the following error message:

What are two causes for this error? (Choose two.)

Options:

A.

There Is excessive SSD load causing the wear leveling to become unbalanced.

B.

A disk is falling.

C.

There is excessive SATA HDD load.

D.

An SSD disk is performing garbage collection to create a dense data layout.

Buy Now
Questions 16

Your customer added a new DS4246 shelf to their FAS2750 single-node system and created a new aggregate on the new shelf. Two weeks later, they log into Active IQ and discover the Medium Impact error shown below.

Shelves with both connections via the same SAS path detected

Referring to the exhibit, which statement is correct?

Options:

A.

In a FAS2750 system, the internal shelf is only seen on one path, and the external shelves are seen on two paths.

B.

The cables are cabled Incorrectly on the SAS stack.

C.

This situation is normal for a FA57750 single-node system.

D.

Active IQ Is not aware of the shelf configuration for a single-node system.

Buy Now
Questions 17

You have a 2-node NetApp FAS2750 switchless cluster with twenty-four 1.8 TB disks that is experiencing performance issues. Upon investigation, you discover several type B consistency points.

Referring to the exhibit, which corrective action would address these consistency points?

Options:

A.

Create additional data LIFs.

B.

Convert the 2-node switchless cluster to a 2-node switched cluster.

C.

Add an additional shelf of twenty-four 1.8 TB disks.

D.

Replace the twenty-four 1.8 TB disks with twelve 4 TB disks.

Buy Now
Questions 18

Your customer is running a NetApp AFF A800 system with NetApp ONTAP 9.8 software and states that their NS224 shelf is not showing with the correct shelf ID. You analyze the data and the shelf shows an identification of “1.SHFHUXXXXXXXXXX."

What is the cause of the reported Issue?

Options:

A.

The shelf has been power cycled.

B.

A new shelf was added to the controller.

C.

The shelf had a disk replaced too quickly.

D.

The shelf was cabled Incorrectly.

Buy Now
Exam Code: NS0-593
Exam Name: NetApp Certified Support Engineer ONTAP Specialist
Last Update: Dec 2, 2024
Questions: 60
$66  $164.99
$50  $124.99
$42  $104.99
buy now NS0-593