A customer is designing a FlexPod solution that must satisfy the requirements shown below:
have disaster recovery to an alternative data center,
must have continuous replication of data for a database,
must leverage a 100Gbps capable switch,
have a maximum distance of 700 km.
In this scenario, which two components would be used to satisfy the requirements? (Choose two.)
A customer plans to decommission a Cisco UCS B-Series server, as part of this action, the customer disassociates the service profile from the currently assigned server.
Which action is performed by UCS Manager in this scenario?
You have taken over management of an existing FlexPod system as part of a new job role. You want to find details of existing support and service contracts available for the system.
Which two resources would you use to find this information? (Choose two.)
A customer wants to upgrade their current VMware vSphere 6.5 environment to vSphere 7.x.
Where would you go to determine which Cisco UCS configurations support this goal?
A customer wants to add 40 Gbps networking capabilities to a FlexPod Datacenter 10 Gbps environment.
Which two Cisco components support this speed? (Choose two.)
In which two sources would you verify scale out maximums for NetApp and Cisco UCS environments? (Choose two.)
A customer wants to deploy a FlexPod Datacenter solution that supports a secure multitenant design with VMware vSphere 6.x as the hypervisor. The customer wants to ensure that virtual machines are encrypted in transit and at rest and restricted to their specified tenant.
Which component should the customer use to implement this capability?
A customer is performing a server refresh of their FlexPod solution to accommodate business growth. The customer is interested in using Cisco C-Series servers, and supporting multiple 40 Gbps link to each server, upgrading from the existing 10 Gbps links.
Which two VICs support these requirements? (Choose two.)
A customer has reviewed the latest vSphere CVD and asks you if they can use their older Cisco servers in the new FlexPod solution and still have supported configuration.
Which statement is true in this scenario?
You want to ass a customer’s NetApp storage controllers into their Cisco Intersight management portal.
In this scenario, which IP address would you choose to add?
A customer wants to replace their Cisco UCS 6248UP with the current Cisco UCS 6454. They are currently using six 16 Gbit uplinks per Fabric Interconnect for FC and do not want to change the speed and number of ports used.
In this scenario, what is the minimum number of unified ports that must be configured for FC for a comparable configuration?
A customer wants to upgrade their code fabric between each site with a modular chassis switch that supports up to 400GbE per port to accommodate more business transaction volume.
In this scenario, which device would help them accomplish their objective?
A customer wants to deploy a FlexPod Datacenter solution in a limited amount of rack space. After planning for the networking and storage devices required for the deployment, they realize they have six rack units of space remaining. They need to install as many servers as possible in this available rack space.
In this scenario, which solution allows them to accomplish their objective?
You are creating a FlexPod with a significant AI workload and would like to use NVIDIA’s SXM2-based GPUs.
Which Cisco UCS server would you use in this scenario?
What are the 1U, rack mountable, Fabric Extenders (FEX) used for in a FlexPod environment?