What type of air conditioner does the Fusion Mod ule800 basic configurations adopt? () (Multiple Choice)
When the UPS5000-S is configured to satisfy N+2 modular redundancy configuration to carry 120 kW loads, a () UPS can be configured.
If the UPS5000-E (50 kVA power module) backs up power without derating, it is unreasonable to configure () 12 V batteries.
An industrial frequency UPS requires extra investment compared with a high frequency UPS, including (): (Multiple Choice)
The input power factor (full load) of the UPS5000A is (), which can efficiently reduce the pollution to the power grid and save the preceding power distribution investment.
The optional components and features in the typical configuration solution of the FusionModule500 include ().
APM and NXR need to derate at 30°C, while the UPS5000-E does not need to derate below 40°C.
Which of the following actions does the UPS2000-A take to deal with excessive operating temperatures?
The rated loading capacity of a 3+0 parallel system is a maximum of () times the rated loading capacity of a single UPS.
Which of the following products is similar to the modular UPSs of the UPS5000-E series in product features?
Which of the following statements are true about the overload capabilities of the various capacity models of the UPS2000-A series (6 kVA to 10 kVA) in normal mode? () (Multiple Choice)
What air conditioner configuration method does the FusionModule800 support? ( )
Which of the following functions and components are configured for the standard UPS5000-E (50 kVA power module)? (Multiple Choice)
For the UPS2000-G series (6 kVA to 20 kVA), the main input voltage ranges from 80 V to 280 V, and the input frequency ranges from 40 Hz to 70 Hz. A wide input range effectively reduces the battery switch times, failure probability, and battery charge/discharge times, helping improve the battery life.
Which of the following conditions shall be considered whencalculating the UPS rated inputcurrent?
(Multiple Choice)
The rated loading capacity of a 2+1 parallel system is a maximum of () times the rated loading capacity of a single UPS.
What differentiated features does the FusionModule800 have over competing products? () (Multiple Choice)
The UPS5000-E can realize convenient and simple N+X power supply system only by configuring a ().
A wide input range effectively reduces the battery switch times, failure probability, and battery charge/discharge times, helping improve the battery life. The input voltage range of the UPS2000-G series (6 kVA to 20 kVA) is ( ).
What is the maximum number of cabinets used by the FusionModule800 respectively? ( )
Which of the following statements are correct about the UPS5000-A (30-120 kVA) reliability? (Multiple Choice)
What differentiated features does the FusionModule500 have over competing products? () (Multiple Choice)
The UPS5000-E can keep a high efficiency and reduce loss within a wide load range. The efficiency can be up to 96% at 40% loads and 95% at 20% loads respectively. What's the efficiency under ECO mode?
The highest temperature in the local area is () when selects T3 air conditioning?
By default, how many PDUs are configured for one cabinet of the FusionModule2000? ( )
If the total current of a battery string is 1000 A and three battery strings are configured, the most economic cable configuration between the UPS and the main switch box is ():
Which of the following communication functions does the UPS5000-E support? (Multiple Choice)
Which of the following items is required if the UPS5000-E adopts both dry contact card and backfeed protection card?
How many batteries does the UPS2000-G series (15 kVA to 20 kVA) support? () (Multiple Choice)
The Fusion Mod ule500 and FusionModule800 must have unified network management software configured for remote WebUI monitoring.
Which of the following advantages does the UPS5000-A have compared with the NXP, 9395, and Galaxy 7000? (Multiple Choice)
By default, how many POUs are configured for one cabinet of the FusionModule2000? ( )
The UPS2000-G series (6 kVA to 20 kVA) supports backup power supplied from battery packs and battery racks. Battery packs can be mounted on racks to save installation space.
The parallel signal cables of the UPS2000-G series (6 kVA to 20 kVA) are connected in () mode, which avoids the impact caused by a faulty parallel cable and enhances parallel system reliability.
The UPS2000-G series (6 kVAto 20 kVA) features an industry-leading lightning protection design, with a lightning protection level of () and a surge protection level of (), which avoids 90% of failures caused by lightning strikes and offers reliable protection for the AC input ports on back-end devices.
Which of the following elements will affect the application of HVDC in the equipment room? (Multiple Choice)
The output power factor of the UPS5000-A-400/500K is (), which can be applicable to new IT loads and greatly improve the loading capacity.
The UPS5000-E features wide voltage and frequency input range. It can be used in severe grid environments and extend the battery service life. What's the maximum input voltage range of the UPS5000-E?
The UPS2000-G supports low voltage disconnection. Which of the following is not a function of low voltage disconnection? ()
Which of the following communication methods doesthe UPS2000-G series (6 kVA to 20 kVA)support?
(Multiple Choice)
Which of the following is not a configuration option of the 20-kVA UPS2000-G? ()
Which of the following components is optional for the UPS5000-E (25-75 kVA)? (Multiple Choice)
When configuring batteries, you do not need to consider the battery brand as long as the capacity satisfies customer requirements.
The capacity of the UPS5000-S power module is 50 kVA, and the height is 2U, which ranks the top in the power density of the industry.
What are the subcategories of data center energy in the product directory tree on the SCT configurator homepage? (Multiple Choice)
When configuring redundant modular UPSs, as long as the number of modules meet the basic requirements, you do not need to consider the distribution of UPS modules in different racks.
The maximum capacity of a single-racked UPS5000-E (50 kVA power module) is 300 kVA.
Which of the following statements are correct about UPS5000-E bypass overload capacity? (Multiple Choice)
Which of the following IP protection level does the UPS5000-E support? (Multiple Choice)
The UPS2000-G series (6 kVA to 20 kVA) supports up to () UPSs in parallel, providing excellent scalability.
The UPS5000-E (50 kVA power module) supports the single cabinet capacity of 300 kVA and supports eight racks used in parallel.
Which of the following products can be quoted in a configurator? (Multiple Choice)
Which of the following statements are incorrect about the UPS 5000-A-400/500K? (Multiple Choice)
If the UPS is configured with thirty-two 12 V batteries, the floating charge voltage is ().
The output power factor of the UPS2000-G series (6 kVA to 20 kVA) is (), which adapts to new types of IT loads and greatly improves the system loading capability.
The built-in SNMP and ModBus card of the UPS5000-A reduce management investment costs for clients.
The UPS5000-A has an industry-leading efficiency. It keeps a high efficiency within a wide load range, which greatly reduces the operating expense (OPEX) for clients. The highest efficiency can be().