H19-311 Sample Questions Answers

Questions 4

What type of air conditioner does the Fusion Mod ule800 basic configurations adopt? () (Multiple Choice)

Options:

A.

In-row air conditioner

B.

Rack-mounted air conditioner

C.

Air cooling

D.

Water cooling

E.

Air conditioner with a heater and humidifier

F.

Cooling only

Buy Now
Questions 5

When the UPS5000-S is configured to satisfy N+2 modular redundancy configuration to carry 120 kW loads, a () UPS can be configured.

Options:

A.

160 kVA

B.

200 kVA

C.

240 kVA

D.

250 kVA

Buy Now
Questions 6

If the UPS5000-E (50 kVA power module) backs up power without derating, it is unreasonable to configure () 12 V batteries.

Options:

A.

34

B.

36

C.

38

D.

40

Buy Now
Questions 7

An industrial frequency UPS requires extra investment compared with a high frequency UPS, including (): (Multiple Choice)

Options:

A.

Equipment room area

B.

Bearing capacity (installation and construction)

C.

Cooling electricity cost

D.

D.G.

E.

Operating electricity cost

Buy Now
Questions 8

Which of the following types does the UPS5000-A belong to?

Options:

A.

High frequency UPS and modular UPS

B.

High-frequency tower-mounted UPS

C.

Industrial frequency UPS

Buy Now
Questions 9

The input power factor (full load) of the UPS5000A is (), which can efficiently reduce the pollution to the power grid and save the preceding power distribution investment.

Options:

A.

1

B.

>0.99

C.

>0.98

Buy Now
Questions 10

The optional components and features in the typical configuration solution of the FusionModule500 include ().

Options:

A.

Huawei tablet, alarm notification over short messages, video surveillance, mobile app, and switch

B.

Huawei tablet, alarm notification over short messages, video surveillance, water sensor, and smoke sensor

C.

Huawei tablet, alarm notification over short messages, mobile app, water sensor, and door status sensor

Buy Now
Questions 11

APM and NXR need to derate at 30°C, while the UPS5000-E does not need to derate below 40°C.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 12

Which of the following actions does the UPS2000-A take to deal with excessive operating temperatures?

Options:

A.

Switch to bypass mode.

B.

Switch to battery mode.

C.

Stop output and power off loads.

D.

No action is taken.

Buy Now
Questions 13

The UPS specifications of the Fusion Mod ule500 include ( ). (Multiple Choice)

Options:

A.

3 kVA

B.

6 kVA

C.

10 kVA

D.

15 kVA

Buy Now
Questions 14

The rated loading capacity of a 3+0 parallel system is a maximum of () times the rated loading capacity of a single UPS.

Options:

A.

3

B.

2

C.

1.6

D.

1.2

Buy Now
Questions 15

Which of the following products is similar to the modular UPSs of the UPS5000-E series in product features?

Options:

A.

Hipulse-U

B.

APM

C.

NXr

D.

80-NET

Buy Now
Questions 16

Which of the following statements are true about the overload capabilities of the various capacity models of the UPS2000-A series (6 kVA to 10 kVA) in normal mode? () (Multiple Choice)

Options:

A.

105%-125%, switch to bypass after 5-miunute continuous loading

B.

125%-150%, switch to bypass after 1-miunute continuous loading

C.

> 150%, switch to bypass after 10s continuous loading

D.

> 150%, switch to bypass after 0.1s continuous loading

Buy Now
Questions 17

What air conditioner configuration method does the FusionModule800 support? ( )

Options:

A.

1+0/1+1

B.

2+0/2+1

C.

1+0/1+1/2+0/2+1

Buy Now
Questions 18

Which of the following functions and components are configured for the standard UPS5000-E (50 kVA power module)? (Multiple Choice)

Options:

A.

SNMP function

B.

Dry contact communication card

C.

Functions of a parallel system

D.

BSC

Buy Now
Questions 19

For the UPS2000-G series (6 kVA to 20 kVA), the main input voltage ranges from 80 V to 280 V, and the input frequency ranges from 40 Hz to 70 Hz. A wide input range effectively reduces the battery switch times, failure probability, and battery charge/discharge times, helping improve the battery life.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 20

Which of the following conditions shall be considered whencalculating the UPS rated inputcurrent?

(Multiple Choice)

Options:

A.

UPS rated output apparent power

B.

UPS operating nominal efficiency

C.

Battery inversion efficiency

D.

UPS battery charging efficiency

Buy Now
Questions 21

The rated loading capacity of a 2+1 parallel system is a maximum of () times the rated loading capacity of a single UPS.

Options:

A.

3

B.

2

C.

1.6

D.

1.2

Buy Now
Questions 22

What differentiated features does the FusionModule800 have over competing products? () (Multiple Choice)

Options:

A.

Rack-mounted frequency-converting air conditioner

B.

Integrated design of cooling and power

C.

Light-load dehumidification of air conditioning

D.

iBattery

Buy Now
Questions 23

The UPS5000-E can realize convenient and simple N+X power supply system only by configuring a ().

Options:

A.

BSC cable

B.

Parallel cable

C.

BSC control board

D.

Parallel card

Buy Now
Questions 24

A wide input range effectively reduces the battery switch times, failure probability, and battery charge/discharge times, helping improve the battery life. The input voltage range of the UPS2000-G series (6 kVA to 20 kVA) is ( ).

Options:

A.

80-280 V

B.

120-280 V

C.

120-300 V

D.

160-300 V

Buy Now
Questions 25

What is the maximum number of cabinets used by the FusionModule800 respectively? ( )

Options:

A.

10

B.

9

C.

8

D.

6

Buy Now
Questions 26

Which of the following statements are correct about the UPS5000-A (30-120 kVA) reliability? (Multiple Choice)

Options:

A.

6 kV/5 kA lightning protection design

B.

Wide input voltage range

C.

High inverter overload capability

D.

Conformal coating technology

Buy Now
Questions 27

What differentiated features does the FusionModule500 have over competing products? () (Multiple Choice)

Options:

A.

Integrated design of cooling and power

B.

Centralized management of multiple data centers

C.

Automatic startup of air conditioners when power supply recovers

D.

iBattery

Buy Now
Questions 28

The UPS5000-E can keep a high efficiency and reduce loss within a wide load range. The efficiency can be up to 96% at 40% loads and 95% at 20% loads respectively. What's the efficiency under ECO mode?

Options:

A.

0.97

B.

0.98

C.

0.96

D.

0.99

Buy Now
Questions 29

The highest temperature in the local area is () when selects T3 air conditioning?

Options:

A.

30-35°C

B.

35-43°C

C.

43-55°C

D.

55-65°C

Buy Now
Questions 30

By default, how many PDUs are configured for one cabinet of the FusionModule2000? ( )

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 31

If the total current of a battery string is 1000 A and three battery strings are configured, the most economic cable configuration between the UPS and the main switch box is ():

Options:

A.

120 mm2 (382 A) x 3

B.

150 mm2 (441 A) x 3

C.

185 mm2 (506 A) x 3

D.

240 mm2 (599 A) x 3

Buy Now
Questions 32

Which of the following communication functions does the UPS5000-E support? (Multiple Choice)

Options:

A.

Dry contact card

B.

RS485

C.

SNMP

D.

RS232

Buy Now
Questions 33

Which of the following items is required if the UPS5000-E adopts both dry contact card and backfeed protection card?

Options:

A.

ECM extended subrack

B.

IP21 component

C.

Dry contact card socket

Buy Now
Questions 34

The UPS5000-E (25-75 kVA) supports a maximum of ( ) battery modules.

Options:

A.

16

B.

128

C.

144

D.

150

Buy Now
Questions 35

The UPS5000-A-400/500K supports () cabling mode.

Options:

A.

Top

B.

Bottom

C.

Top and bottom

Buy Now
Questions 36

How many batteries does the UPS2000-G series (15 kVA to 20 kVA) support? () (Multiple Choice)

Options:

A.

28

B.

32

C.

36

D.

40

Buy Now
Questions 37

The Fusion Mod ule500 and FusionModule800 must have unified network management software configured for remote WebUI monitoring.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 38

Which of the following advantages does the UPS5000-A have compared with the NXP, 9395, and Galaxy 7000? (Multiple Choice)

Options:

A.

Input voltage range

B.

Efficiency

C.

Floor area

Buy Now
Questions 39

By default, how many POUs are configured for one cabinet of the FusionModule2000? ( )

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 40

The UPS2000-G series (6 kVA to 20 kVA) supports backup power supplied from battery packs and battery racks. Battery packs can be mounted on racks to save installation space.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 41

The parallel signal cables of the UPS2000-G series (6 kVA to 20 kVA) are connected in () mode, which avoids the impact caused by a faulty parallel cable and enhances parallel system reliability.

Options:

A.

Ring

B.

∆-shaped

C.

Y-shaped

D.

Single cable connection

Buy Now
Questions 42

The UPS2000-G series (6 kVAto 20 kVA) features an industry-leading lightning protection design, with a lightning protection level of () and a surge protection level of (), which avoids 90% of failures caused by lightning strikes and offers reliable protection for the AC input ports on back-end devices.

Options:

A.

5 kA; 6 kV

B.

2kA;4kV

C.

2kA;6kV

D.

4kA;6kV

Buy Now
Questions 43

Which of the following elements will affect the application of HVDC in the equipment room? (Multiple Choice)

Options:

A.

The standard is not complete, and multiple 240 V/336 V systems exist.

B.

Not all loads can use the DC power supply directly,

C.

The cost of DC circuit breaker components is high.

D.

The efficiency is low.

Buy Now
Questions 44

The output power factor of the UPS5000-A-400/500K is (), which can be applicable to new IT loads and greatly improve the loading capacity.

Options:

A.

0.9

B.

0.95

C.

0.8

D.

1

Buy Now
Questions 45

The UPS5000-E features wide voltage and frequency input range. It can be used in severe grid environments and extend the battery service life. What's the maximum input voltage range of the UPS5000-E?

Options:

A.

305-485 V

B.

105-485 V

C.

138-485 V

Buy Now
Questions 46

The UPS2000-G supports low voltage disconnection. Which of the following is not a function of low voltage disconnection? ()

Options:

A.

When overload occurs, secondary loads are closed to remove the overload.

B.

When the UPS2000-G is powered by batteries, secondary loads are closed to prolong the backup time for important loads.

C.

When the UPS2000-G is powered by batteries, secondary loads are closed for battery protection.

D.

The purpose of closing secondary loads is to adjust the load ratio and optimize the operating efficiency.

Buy Now
Questions 47

Which of the following communication methods doesthe UPS2000-G series (6 kVA to 20 kVA)support?

(Multiple Choice)

Options:

A.

RS-232

B.

RS-485

C.

SNMP

D.

USB

E.

Dry contact

Buy Now
Questions 48

Which of the following is not a configuration option of the 20-kVA UPS2000-G? ()

Options:

A.

4+0

B.

3+1

C.

Dual-bus system

D.

Battery string sharing

Buy Now
Questions 49

The UPS5000-A 30-120 kVA can be wall-mounted.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 50

Which of the following components is optional for the UPS5000-E (25-75 kVA)? (Multiple Choice)

Options:

A.

Anti-seismic kit

B.

Top outlet kit

C.

Ambient temperature and humidity sensor

D.

BSC cable

Buy Now
Questions 51

When configuring batteries, you do not need to consider the battery brand as long as the capacity satisfies customer requirements.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 52

The capacity of the UPS5000-S power module is 50 kVA, and the height is 2U, which ranks the top in the power density of the industry.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 53

What are the subcategories of data center energy in the product directory tree on the SCT configurator homepage? (Multiple Choice)

Options:

A.

UPS

B.

Air conditioner

C.

PDC

D.

Modular Data Center

Buy Now
Questions 54

When configuring redundant modular UPSs, as long as the number of modules meet the basic requirements, you do not need to consider the distribution of UPS modules in different racks.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 55

The maximum capacity of a single-racked UPS5000-E (50 kVA power module) is 300 kVA.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 56

The UPS5000-S efficiency is ().

Options:

A.

0.96

B.

0.965

C.

0.971

D.

0.975

Buy Now
Questions 57

Which of the following statements are correct about UPS5000-E bypass overload capacity? (Multiple Choice)

Options:

A.

125% overload for 10 minutes

B.

125% overload for 60 minutes

C.

135% overload for a long time

D.

1000% overload for 100 ms

Buy Now
Questions 58

Which of the following IP protection level does the UPS5000-E support? (Multiple Choice)

Options:

A.

IP20

B.

IP21

C.

IP41

D.

IP55

Buy Now
Questions 59

The UPS2000-G series (6 kVA to 20 kVA) supports up to () UPSs in parallel, providing excellent scalability.

Options:

A.

0

B.

2

C.

3

D.

4

Buy Now
Questions 60

The UPS5000-E (50 kVA power module) supports the single cabinet capacity of 300 kVA and supports eight racks used in parallel.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 61

Which of the following products can be quoted in a configurator? (Multiple Choice)

Options:

A.

UPS2000-G

B.

UPS5000-E

C.

FusionModule2000

D.

UPS8000

Buy Now
Questions 62

Which of the following statements are incorrect about the UPS 5000-A-400/500K? (Multiple Choice)

Options:

A.

The input power factor is 0.99.

B.

The output power factor is 1.

C.

The number of batteries cannot be adjusted.

D.

The efficiency is 94%.

Buy Now
Questions 63

If the UPS is configured with thirty-two 12 V batteries, the floating charge voltage is ().

Options:

A.

432 V

B.

451V

C.

540V

D.

564 V

Buy Now
Questions 64

The output power factor of the UPS2000-G series (6 kVA to 20 kVA) is (), which adapts to new types of IT loads and greatly improves the system loading capability.

Options:

A.

0.7

B.

0.8

C.

0.9

D.

0.99

Buy Now
Questions 65

The UPS5000-E (25-125 kVA) only supports top cable routing.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 66

The built-in SNMP and ModBus card of the UPS5000-A reduce management investment costs for clients.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 67

The UPS5000-A has an industry-leading efficiency. It keeps a high efficiency within a wide load range, which greatly reduces the operating expense (OPEX) for clients. The highest efficiency can be().

Options:

A.

0.95

B.

0.96

C.

0.97

Buy Now